From: BennyLoop on
Hi there:

I just published a program that will serve as an instrument to an experiment.
All went fine except on the last screen.

On the last screen there is some text telling them that they're done and to
press the "quit" button to end the exercise.

Upon this, an error message pops up saying "Cannot complete CMI operation b/c
the CMI Scripting Xtra was not found or could not be initiated"

Then there is a continue button or an ignore all other errors button.

The program then closes and there are no other problems.

Can someone help removing this error message from the published file?

The calculation I'm using on the quit button is Quit(0).

Thanks

From: Amy Blankenship on

"BennyLoop" <webforumsuser(a)macromedia.com> wrote in message
news:g5obok$h42$1(a)forums.macromedia.com...
> Hi there:
>
> I just published a program that will serve as an instrument to an
> experiment.
> All went fine except on the last screen.
>
> On the last screen there is some text telling them that they're done and
> to
> press the "quit" button to end the exercise.
>
> Upon this, an error message pops up saying "Cannot complete CMI operation
> b/c
> the CMI Scripting Xtra was not found or could not be initiated"
>
> Then there is a continue button or an ignore all other errors button.
>
> The program then closes and there are no other problems.
>
> Can someone help removing this error message from the published file?
>
> The calculation I'm using on the quit button is Quit(0).

It sounds like you're doing some user tracking but didn't include the Xtra
for that, which I think might be PWInt.x32, but I can't remember exactly.

HTH;

Amy


From: BennyLoop on
Thanks Amy. That's exactly what it was.

Ben
From: Steve Howard **Community Expert** - eLearning + Mobile and Devices on

> I just published a program that will serve as an instrument to an
> experiment.
> All went fine except on the last screen.
>
> On the last screen there is some text telling them that they're done and
> to
> press the "quit" button to end the exercise.
>
> Upon this, an error message pops up saying "Cannot complete CMI operation
> b/c
> the CMI Scripting Xtra was not found or could not be initiated"
>
> Then there is a continue button or an ignore all other errors button.
>
> The program then closes and there are no other problems.
>
> Can someone help removing this error message from the published file?
>
> The calculation I'm using on the quit button is Quit(0).

Include the pwint x32 file, or uncheck Knowledge Track in the CMI tab of
file properties, then republish.

Steve


--
http://twitter.com/Stevehoward999

Adobe Community Expert: eLearning, Mobile and Devices
European eLearning Summit - EeLS
Adobe-sponsored eLearning conference.
http://www.elearningsummit.eu