From: Pete Fraser on
"Steve Pope" <spope33(a)speedymail.org> wrote in message
news:i3n53q$9sq$1(a)blue.rahul.net...

> Back to the OP's problem -- it occurs to me that if he is intending to
> use fdatool's design path through to HDL generation,

I'd be prepared to use the tool's HDL generation, but assumed
that it probably wouldn't do what I needed. I have a relatively low
sample rate, so I was just going to use a pool of memory and a MAC,
and put all the complexity in the memory control. I can't find
any way of making the Matlab HDL generator do that
(nor did I really expect to).

> then he is
> probably stuck figuring out how the tool's fixed-point modes work,
> thus making the advice given in this thread of limited value.
>
> (But I would still do a grounds-up quantization study independent of
> the tool even in this case, approaching it as I outlined in
> response to OP's previous question.)

I think I'll have to do that. I just need to get some familiarity with
Matlab first (any paper / text you could recommend on doing a
grounds up quantization study on an IIR?).

It seemed to me that the FDATool pretty much did what I needed,
but as I began to work with it I realized some of the answers I was
getting were counter-intuitive. For relatively wide LPFs, the default
quantization choices seem to be reasonable. The noise analysis
shows about 60 dB stop-band artifacts, but I can increase
accuracy at various points in the filter, and get the performance I need.

It's when I try to understand what the various controls mean that I
get a bit frustrated. The documentation just expands slightly on
the titles of the boxes, but doesn't really explain anything.
For example, the default 6th order Butterworth LPF has an input
of 16-bits with 15 fractional, and an output of 16-bits with 10 fractional.
Why would I need anything more than two bits before the binary
pont on the output? Clearly I don't understand what their
nomenclature means, but I can't find any detailed information (I know
I've repeated myself with a previous question, but I'm hoping
someone on the matlab group might answer).

Things get worse when I go to higher accuracy and narrower filters.
If I start looking at a filter with f3db = 0.05, things get messy. The
response
is ugly, the stop-band artifacts are extremely high, and the tool does
things I don't expect. It doesn't seem to default to higher accuracy in the
data path for narrower filters, but when I change to higher accuracy the
performance gets much worse. I'm not sure if the tool is broken, I'm
ignorant, or a combination of the two (wierd rendering bugs in the GUI don't
fill me with confidence though.).

I seem to get bad results with any architecture. DF2SOS is weird, but
I tried Steve's earlier suggestion of ARMA, and converted a 6th
order Butterworth LPF with f3db = 0.05 to ARMA. The floating
point response looks fine, but converting to fixed point with the
tool's defaults gives me a Magnitude Response Estimate of about -80 dB
from DC to Nyquist. Doubling the number of bits everywhere gives me
an MRE of -140 dB from DC to Nyquist (note, this is Magnitude
Response Estimate -- not Noise Power Spectrum).

I've also got to decide whether / what I'm buying from Mathworks
(the current system is a loaner). I started off liking its power, but am
now thinking it's either buggy or I'm too stupid to use it.

Thanks

Pete




From: Steve Pope on
Pete Fraser <pfraser(a)covad.net> wrote:

>Things get worse when I go to higher accuracy and narrower filters.
>If I start looking at a filter with f3db = 0.05, things get messy. The
>response
>is ugly, the stop-band artifacts are extremely high, and the tool does
>things I don't expect. It doesn't seem to default to higher accuracy in the
>data path for narrower filters, but when I change to higher accuracy the
>performance gets much worse. I'm not sure if the tool is broken, I'm
>ignorant, or a combination of the two (wierd rendering bugs in the GUI don't
>fill me with confidence though.).

>I seem to get bad results with any architecture. DF2SOS is weird, but
>I tried Steve's earlier suggestion of ARMA, and converted a 6th
>order Butterworth LPF with f3db = 0.05 to ARMA. The floating
>point response looks fine, but converting to fixed point with the
>tool's defaults gives me a Magnitude Response Estimate of about -80 dB
>from DC to Nyquist. Doubling the number of bits everywhere gives me
>an MRE of -140 dB from DC to Nyquist (note, this is Magnitude
>Response Estimate -- not Noise Power Spectrum).

I don't necessarily see the above as bad results, other than the
non-controllability of the tool, but I do not know your dynamic
range requirements. Maybe you have extreme requirements and will
need to use floating point arithmetic in your implementation;
that sometimes happens.

The last time I had to design a comparable Butterworth filter, it required
a dynamic range of about 80 dB, and I ended up with the following
precisions in a lattice (ARMA) structure: 22 bit internal data, and 12
bit coefficients. This was a 4th order filter with a passband
of 0.01 * Fs. The internal data values required four additional
bits to the left of the binary point than did the input value.
This seems (roughly) comparable to what you're trying to do.

As I mentioned, I like to plot RMS error (in dBc) vs. input signal level
(in dB relative to some nominal level) to visualize quantization
effects. Such a plot should typically have a flat floor in the middle of
the usable range (representing the limits of your coefficient
quantization; this includes your stop-band artifacts); it should have a
6 dB/octave slope in the lower-signal range (resulting from the data-path
quantization); and a steep saturating effect at high signal levels. If
you do not obtain this sort of U-shaped or V-shaped curve, something is
seriously wrong.

(I do not think this is one of the plots fdatool likes to spit out on
its own.)


Steve
From: Steve Pope on
Steve Pope <spope33(a)speedymail.org> wrote:

>it should have a
>6 dB/octave slope in the lower-signal range (resulting from the data-path
>quantization);

Oops.. meant to say a slope of one (6dB per 6dB).


S.
From: Pete Fraser on
"Steve Pope" <spope33(a)speedymail.org> wrote in message
news:i3nu2p$u18$1(a)blue.rahul.net...
> Pete Fraser <pfraser(a)covad.net> wrote:

>>but converting to fixed point with the
>>tool's defaults gives me a Magnitude Response Estimate of about -80 dB
>>from DC to Nyquist. Doubling the number of bits everywhere gives me
>>an MRE of -140 dB from DC to Nyquist (note, this is Magnitude
>>Response Estimate -- not Noise Power Spectrum).
>
> I don't necessarily see the above as bad results, other than the
> non-controllability of the tool,

Perhaps we're talking at cross purposes here, or there's something
I don't understand. The Magnitude response estimate is -80 dB
at DC. It should be 0 dB in the passband.

> but I do not know your dynamic
> range requirements. Maybe you have extreme requirements and will
> need to use floating point arithmetic in your implementation;
> that sometimes happens.

I don't think so. 96 dB should be fine.
I've got ample FPGA, and the data rate is slow, so I can go to very
high fixed-point accuracy if I need to.

> The last time I had to design a comparable Butterworth filter, it required
> a dynamic range of about 80 dB, and I ended up with the following
> precisions in a lattice (ARMA) structure: 22 bit internal data, and 12
> bit coefficients. This was a 4th order filter with a passband
> of 0.01 * Fs. The internal data values required four additional
> bits to the left of the binary point than did the input value.
> This seems (roughly) comparable to what you're trying to do.

It does. I need 6th order, and 96 dB dynamic range, but I've
been setting FDATool to much greater coefficient accuracies and
data-path resolutions than you're suggesting. There must be some
aspect of the tool I'm not understanding (or, as Rick Lyons suggested,
there are problems with it).

> As I mentioned, I like to plot RMS error (in dBc) vs. input signal level
> (in dB relative to some nominal level) to visualize quantization
> effects. Such a plot should typically have a flat floor in the middle of
> the usable range (representing the limits of your coefficient
> quantization; this includes your stop-band artifacts); it should have a
> 6 dB/octave slope in the lower-signal range (resulting from the data-path
> quantization); and a steep saturating effect at high signal levels. If
> you do not obtain this sort of U-shaped or V-shaped curve, something is
> seriously wrong.

I'll give that a try.
Do you use Matlab for this?
If so, what toolboxes do you need?

The Mathworks is going to want money from me soon, and
I'll need to decide what tool boxes to buy.
>
> (I do not think this is one of the plots fdatool likes to spit out on
> its own.)

It's not.

Thanks

Pete


From: Steve Pope on
Pete Fraser <pfraser(a)covad.net> wrote:

>"Steve Pope" <spope33(a)speedymail.org> wrote in message

>> Pete Fraser <pfraser(a)covad.net> wrote:

>>>but converting to fixed point with the
>>>tool's defaults gives me a Magnitude Response Estimate of about -80 dB
>>>from DC to Nyquist. Doubling the number of bits everywhere gives me
>>>an MRE of -140 dB from DC to Nyquist (note, this is Magnitude
>>>Response Estimate -- not Noise Power Spectrum).

>> I don't necessarily see the above as bad results, other than the
>> non-controllability of the tool,

>Perhaps we're talking at cross purposes here, or there's something
>I don't understand. The Magnitude response estimate is -80 dB
>at DC. It should be 0 dB in the passband.

Okay that's not good.

But it looked okay in full floating point?

Do you have the option of quantizing just the coefficients, and
not the data path? That is the first step.

What precision coefficients results in a 80 dB response error at DC?

>It does. I need 6th order, and 96 dB dynamic range, but I've
>been setting FDATool to much greater coefficient accuracies and
>data-path resolutions than you're suggesting. There must be some
>aspect of the tool I'm not understanding (or, as Rick Lyons suggested,
>there are problems with it).

Yes, it's not sure it is worth the time to sort this out, when
you have just one filter to design. The (full-precision) coefficients
themselves are probably good; and you can just go with them in a design.
However it seems the tool is not helping you make other design
decisions, such as DF vs. ARMA, or helping you study precisions.

Steve
First  |  Prev  |  Next  |  Last
Pages: 1 2 3
Prev: FFT Return Values
Next: free space optics....