From: Robert Baer on
Jamie wrote:
> JW wrote:
>
>> So there you are, working on something that you don't have any schematics
>> for; (in this case a Datron 1281 8.5 digit DMM) This one wouldn't power
>> up. Poking around I noticed some (TTL) circuits were not getting +5VDC.
>> Traced it back through a three terminal linear regulator to it's AC
>> input.
>> Hmmm... Only getting about 5.5VAC, not enough there. Isolate the AC
>> output
>> from the transformer to make sure it wasn't a loading issue; it's not.
>> Gets to about 5.8VAC. This unit has two toroid transformers, and the one
>> I've traced the problem to has 8 wires on the secondary and another 8 on
>> the primary (sheesh)
>>
>> I have no idea what the primary voltages should be (As it turns out,
>> about
>> 16VAC. Weird!)
>>
>> BUT, suddenly I hear a metallic sounding "tick!" and the unit begins
>> running. (I quickly measure the primaries and note the voltages JIC.)
>> sounds a bit like a relay, but there's nothing like that in any of the
>> power supplies (there's a number of them) that I can see. Figuring an
>> intermittent somewhere I begin jiggling connectors, tapping around with a
>> screwdriver handle, etc. Nothing. Meter keeps working.
>>
>> Cold blasts from freeze spray, Heat gun, etc. Nothing.
>> Turn it off for an hour and back on repeating what I did above. Still
>> working.
>>
>> Turn it off for a day and back on. Wash, rinse, repeat. still working
>> perfectly.
>>
>> Things like this seem to happen to me often. Is it just me, or do you
>> have
>> faults like this that drive you nuts?
>>
>> I don't suppose anyone might have any schematics for this meter, would
>> they? I think at some point Datron sold off to Wavetek then Fluke
>> ended up
>> with it, as the user manual is available from Fluke.
>>
>> Thanks.
>>
>>
> Electrolytics will intermit like this. Change all that are in the power
> supply section.
>
>
Yah, i have run into wierd operation / no operation; back and forth;
more than enough to drive anyone nuts (maybe that is why i am so weird?)_.
At one place i worked, there was this HP programmable automatic
tester, tied to (an added) keypunch for data logging.
Worked for months then stopped working.
Started signal tracing with a VOM starting at the keypunch.
Back in those dayz that is all the was, but i would have chosen to
use a VOM over a DVM so i would not miss data pulses.
Got a few feet from the keypunch solenoids to input connector and
then (no sound) it worked; for weeks.
Next time it failed, i checked the cable from keypunch toward the
ATE, but it immediately started working as i started the cable test AT
the keypunch; worked for weeks.
Next time, i started with the interface circuitry at the ATE; you
guessed it - 15 seconds later it worked; yup! for weeks.
And so on; testing creeping to the middle: the cable.
Never got there; was about two inches away from the cable connector
at the ATE the last time i tested the beast.
Never failed again.

All you can do, is leave the damn thing alone as long as it is
working, ignore the hassles, forget them and go on.
But to keep Mister Justin Case mollified, do not totally forget what
you did so that you can pickup the testing gauntlet where ever you
previously left off.
From: JW on
On Wed, 14 Jul 2010 11:32:59 -0400 Jamie
<jamie_ka1lpa_not_valid_after_ka1lpa_(a)charter.net> wrote in Message id:
<oHk%n.13501$0A5.4819(a)newsfe22.iad>:

>JW wrote:
>
>> So there you are, working on something that you don't have any schematics
>> for; (in this case a Datron 1281 8.5 digit DMM) This one wouldn't power
>> up. Poking around I noticed some (TTL) circuits were not getting +5VDC.
>> Traced it back through a three terminal linear regulator to it's AC input.
>> Hmmm... Only getting about 5.5VAC, not enough there. Isolate the AC output
>> from the transformer to make sure it wasn't a loading issue; it's not.
>> Gets to about 5.8VAC. This unit has two toroid transformers, and the one
>> I've traced the problem to has 8 wires on the secondary and another 8 on
>> the primary (sheesh)
>>
>> I have no idea what the primary voltages should be (As it turns out, about
>> 16VAC. Weird!)
>>
>> BUT, suddenly I hear a metallic sounding "tick!" and the unit begins
>> running. (I quickly measure the primaries and note the voltages JIC.)
>> sounds a bit like a relay, but there's nothing like that in any of the
>> power supplies (there's a number of them) that I can see. Figuring an
>> intermittent somewhere I begin jiggling connectors, tapping around with a
>> screwdriver handle, etc. Nothing. Meter keeps working.
>>
>> Cold blasts from freeze spray, Heat gun, etc. Nothing.
>>
>> Turn it off for an hour and back on repeating what I did above. Still
>> working.
>>
>> Turn it off for a day and back on. Wash, rinse, repeat. still working
>> perfectly.
>>
>> Things like this seem to happen to me often. Is it just me, or do you have
>> faults like this that drive you nuts?
>>
>> I don't suppose anyone might have any schematics for this meter, would
>> they? I think at some point Datron sold off to Wavetek then Fluke ended up
>> with it, as the user manual is available from Fluke.
>>
>> Thanks.
>>
>>
>Electrolytics will intermit like this. Change all that are in the power
>supply section.

Not the case here, problem lies in the AC somewhere. When the problem was
happening, the AC voltage on the toroids primary was at about 6 volts or
so, when it should have been 16.
From: JW on
On Wed, 14 Jul 2010 16:18:40 +0000 (UTC) Cydrome Leader
<presence(a)MUNGEpanix.com> wrote in Message id:
<i1ko10$bl8$2(a)reader1.panix.com>:

>In sci.electronics.repair JW <none(a)dev.null> wrote:
>> So there you are, working on something that you don't have any schematics
>> for; (in this case a Datron 1281 8.5 digit DMM) This one wouldn't power
>> up. Poking around I noticed some (TTL) circuits were not getting +5VDC.
>> Traced it back through a three terminal linear regulator to it's AC input.
>> Hmmm... Only getting about 5.5VAC, not enough there. Isolate the AC output
>> from the transformer to make sure it wasn't a loading issue; it's not.
>> Gets to about 5.8VAC. This unit has two toroid transformers, and the one
>> I've traced the problem to has 8 wires on the secondary and another 8 on
>> the primary (sheesh)
>>
>> I have no idea what the primary voltages should be (As it turns out, about
>> 16VAC. Weird!)
>
>Does this unit use an IEC type power receptable with some sort of voltage
>changing/fuse module that might need to be reseated or checked?

Will check that, thanks. This meter is a bit of a rats nets of wiring,
typical of other British test equipment I've worked on (Wayne Kerr for
example). I hope that Fluke cleaned it up when they took it over...

It is interesting to note that some of the other 5 volt supplies were
working, as well as some of the +-15 volt ones. They may be derived from
the other toroid, though.
From: Jamie on
Robert Baer wrote:

> Jamie wrote:
>
>> JW wrote:
>>
>>> So there you are, working on something that you don't have any
>>> schematics
>>> for; (in this case a Datron 1281 8.5 digit DMM) This one wouldn't power
>>> up. Poking around I noticed some (TTL) circuits were not getting +5VDC.
>>> Traced it back through a three terminal linear regulator to it's AC
>>> input.
>>> Hmmm... Only getting about 5.5VAC, not enough there. Isolate the AC
>>> output
>>> from the transformer to make sure it wasn't a loading issue; it's not.
>>> Gets to about 5.8VAC. This unit has two toroid transformers, and the one
>>> I've traced the problem to has 8 wires on the secondary and another 8 on
>>> the primary (sheesh)
>>>
>>> I have no idea what the primary voltages should be (As it turns out,
>>> about
>>> 16VAC. Weird!)
>>>
>>> BUT, suddenly I hear a metallic sounding "tick!" and the unit begins
>>> running. (I quickly measure the primaries and note the voltages JIC.)
>>> sounds a bit like a relay, but there's nothing like that in any of the
>>> power supplies (there's a number of them) that I can see. Figuring an
>>> intermittent somewhere I begin jiggling connectors, tapping around
>>> with a
>>> screwdriver handle, etc. Nothing. Meter keeps working.
>>>
>>> Cold blasts from freeze spray, Heat gun, etc. Nothing.
>>> Turn it off for an hour and back on repeating what I did above. Still
>>> working.
>>>
>>> Turn it off for a day and back on. Wash, rinse, repeat. still working
>>> perfectly.
>>>
>>> Things like this seem to happen to me often. Is it just me, or do you
>>> have
>>> faults like this that drive you nuts?
>>>
>>> I don't suppose anyone might have any schematics for this meter, would
>>> they? I think at some point Datron sold off to Wavetek then Fluke
>>> ended up
>>> with it, as the user manual is available from Fluke.
>>>
>>> Thanks.
>>>
>>>
>> Electrolytics will intermit like this. Change all that are in the
>> power supply section.
>>
>>
> Yah, i have run into wierd operation / no operation; back and forth;
> more than enough to drive anyone nuts (maybe that is why i am so weird?)_.
> At one place i worked, there was this HP programmable automatic
> tester, tied to (an added) keypunch for data logging.
> Worked for months then stopped working.
> Started signal tracing with a VOM starting at the keypunch.
> Back in those dayz that is all the was, but i would have chosen to use
> a VOM over a DVM so i would not miss data pulses.
> Got a few feet from the keypunch solenoids to input connector and then
> (no sound) it worked; for weeks.
> Next time it failed, i checked the cable from keypunch toward the ATE,
> but it immediately started working as i started the cable test AT the
> keypunch; worked for weeks.
> Next time, i started with the interface circuitry at the ATE; you
> guessed it - 15 seconds later it worked; yup! for weeks.
> And so on; testing creeping to the middle: the cable.
> Never got there; was about two inches away from the cable connector at
> the ATE the last time i tested the beast.
> Never failed again.
>
> All you can do, is leave the damn thing alone as long as it is
> working, ignore the hassles, forget them and go on.
> But to keep Mister Justin Case mollified, do not totally forget what
> you did so that you can pickup the testing gauntlet where ever you
> previously left off.

We had a coil in a reversing relay that would intermittently not work
and cause the mechanical drive train to push off in never never land,
thus damaging some very expensive rotor cones. It finally got bad enough
at one point where we were able to fine it.

It turns out that this "GE" reversing contact assembly used pushed on
spades in side to make it's wire termination to the coil instead of
soldering them!>. And you had to unassembled parts not intended to be
unassembled to find this. The mechanical vibration of the unit would
cause a connection issue and not switch on the coil for the reverse
operation when needed... The other controls would just keep cranking the
motor trying to find the correct location when it was actually pushing
it out of sight! And no, there were no limiting sensors in this machine ;)