From: Pablo on
Hi, I would like to know if anyone has received this message when he
tries to start XMD.

This message appears some times and I have to close Xmd Windows and
start again so the message doesn't appear. I use Xilinx Parallel IV
Cable and version 8.2 for EDK.

Thanks.



PowerPC405(1) : ppc405_0
Address Map for Processor ppc405_0
(0x00000000-0x01ffffff) opb_ddr_0 plb->plb2opb->opb
(0x41200000-0x4120ffff) opb_intc_0 plb->plb2opb->opb
(0x41400000-0x4140ffff) opb_mdm_0 plb->plb2opb->opb
(0x41c00000-0x41c0ffff) opb_timer_1 plb->plb2opb->opb
(0xfffe0000-0xffffffff) plb_bram_if_cntlr_1 plb

PowerPC405(2) : ppc405_1
Address Map for Processor ppc405_1

Connecting to cable (Parallel Port - LPT1).
Checking cable driver.
Driver windrvr6.sys version = 8.1.1.0. LPT base address = 0378h.
ECP base address = 0778h.
ECP hardware is detected.
Cable connection established.
Connecting to cable (Parallel Port - LPT1) in ECP mode.
Checking cable driver.
Driver xpc4drvr.sys version = 1.0.4.0. LPT base address = 0378h.
-------------------------------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------------------------------
DeviceIoControl LPT_READ_BUFFER Failed.
Loopback test failed. Sent character = 7F, Received character = FF.
The hardware may be malfunctioning or the BIOS setting for the
Parallel port is
not set to ECP mode.
Cable connection failed.
-------------------------------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------------------------------
Connecting to cable (Parallel Port - LPT1).
Checking cable driver.
Driver windrvr6.sys version = 8.1.1.0. LPT base address = 0378h.
ECP base address = 0778h.
Cable connection established.
ECP port test failed. Using download cable in compatibility mode.
INFO:MDT - Assumption: Selected Device 1 for debugging.

JTAG chain configuration
--------------------------------------------------
Device ID Code IR Length Part Name
1 0127e093 14 XC2VP30

XMD: Connected to PowerPC target. Processor Version No : 0x200108a0
Address mapping for accessing special PowerPC features from XMD/GDB:
I-Cache (Data) : Disabled
I-Cache (Tag) : Disabled
D-Cache (Data) : Disabled
D-Cache (Tag) : Disabled
ISOCM : Disabled
TLB : Disabled
DCR : Disabled

Connected to "ppc" target. id = 0
Starting GDB server for "ppc" target (id = 0) at TCP port no 1234
XMD%