From: Pablo on 21 Apr 2008 05:14 Hi, I would like to know if anyone has received this message when he tries to start XMD. This message appears some times and I have to close Xmd Windows and start again so the message doesn't appear. I use Xilinx Parallel IV Cable and version 8.2 for EDK. Thanks. PowerPC405(1) : ppc405_0 Address Map for Processor ppc405_0 (0x00000000-0x01ffffff) opb_ddr_0 plb->plb2opb->opb (0x41200000-0x4120ffff) opb_intc_0 plb->plb2opb->opb (0x41400000-0x4140ffff) opb_mdm_0 plb->plb2opb->opb (0x41c00000-0x41c0ffff) opb_timer_1 plb->plb2opb->opb (0xfffe0000-0xffffffff) plb_bram_if_cntlr_1 plb PowerPC405(2) : ppc405_1 Address Map for Processor ppc405_1 Connecting to cable (Parallel Port - LPT1). Checking cable driver. Driver windrvr6.sys version = 8.1.1.0. LPT base address = 0378h. ECP base address = 0778h. ECP hardware is detected. Cable connection established. Connecting to cable (Parallel Port - LPT1) in ECP mode. Checking cable driver. Driver xpc4drvr.sys version = 1.0.4.0. LPT base address = 0378h. ------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------- DeviceIoControl LPT_READ_BUFFER Failed. Loopback test failed. Sent character = 7F, Received character = FF. The hardware may be malfunctioning or the BIOS setting for the Parallel port is not set to ECP mode. Cable connection failed. ------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------- Connecting to cable (Parallel Port - LPT1). Checking cable driver. Driver windrvr6.sys version = 8.1.1.0. LPT base address = 0378h. ECP base address = 0778h. Cable connection established. ECP port test failed. Using download cable in compatibility mode. INFO:MDT - Assumption: Selected Device 1 for debugging. JTAG chain configuration -------------------------------------------------- Device ID Code IR Length Part Name 1 0127e093 14 XC2VP30 XMD: Connected to PowerPC target. Processor Version No : 0x200108a0 Address mapping for accessing special PowerPC features from XMD/GDB: I-Cache (Data) : Disabled I-Cache (Tag) : Disabled D-Cache (Data) : Disabled D-Cache (Tag) : Disabled ISOCM : Disabled TLB : Disabled DCR : Disabled Connected to "ppc" target. id = 0 Starting GDB server for "ppc" target (id = 0) at TCP port no 1234 XMD%
|
Pages: 1 Prev: ANNOUNCE: Maia 0.8.2: module-level HDL verification tool Next: OPB_MDM functionality |